Loading... Please wait...

4233 Differential Probe 1:10/100, 100 MHz, 700V

4233 Differential Probe 1:10/100, 100 MHz, 700V

$895.00
Quantity

Product Description





Differential Probe for Power management- Model 4233

The 4233 meets EN61010 Category III Requirements. With wide choice of attenuation
ration, the 4233 is capable of making full range (from millivolts to + 700V) measurements of
floating signals in power electronic circuits.

Features
-Up to +/-1400 V(DC + Peak AC) Differential and Common Mode
-Safety Certified-Bandwidth up to 100 MHz

Applications
-Switching Power Supply Design
-Motor Drive Design
-Electronic Ballast Design
-CTR Display Design

Included
-Black Storage Box
-Red & Black Sprung Hooks
-Calibration Certificate
-4ea AA Batteries
-9 VDC Adapter

Product image

 

Optional 4200 Series Accessories

 

Included with Probe
blackbox.jpg
Black Storage
Box
&
9VDC Adapter
 
 
 
 
 
 
 
 
 

 

4233 Specifications

Bandwidth DC to 100 MHz (-3dB)
Attenuation 1:10/100
Accuracy +/-2%
Input Impedance 4Mohm //7pF each side to ground
Input Voltage
-Category
- Differential Range*

-Common Mode Range*
-Absolute Max. Voltage*(Differential or Common Mode)

CAT III
70Vrms and +/- 70V(DC + Peak AC @ 1/10
700Vrms and +/- 700V(DC + Peak AC) @ 1/100
700Vrms and +/- 700V(DC + Peak AC) @ 1/10 & 1/100
1000Vrms and +/-1000V(DC + Peak AC) @ 1/10 & 1/100
Output Voltage

- Swing (into 50 kohm load
-Offset (typical)
-Noise (typical)
- Source Impedance


 +/-7V
<+/-5m
V0.9m Vrms
50 ohm (for using 1 Mohm input system oscilloscope)
CMMR (typical) -85dB @ 50Hz, -55dB @ 1MHz
Ambient Operating Temperature -10 to 40 degree centigrade
Ambient Storage Temperature -30 to 70 degree centigrade
Ambient Operating Humidity Up to 85% RH
Ambient Storage Humidy Up to 85% RH
Power Requirements** -Standard-options 4 x AA cells or 9 VDC 120mA mains adapter (Both included)
-Optional- Power Leads Power Leads
Length of BNC Cable 36"
Length of Input Leads 12"
Weight 0.9 lb
Dimensions 8" x 3 1/4" x 1 1/2"

*Voltage limit is the lesser of the DC + Peak AC and RMS values.**
a. The supplied voltage must be less than 12V and greater than 4.4V, otherwize the probe could be damagedor will not operate properly.
b. polarity is "+" inside and "V" outside. For wrong polarity, built-in circuit protects the probe, no danger ordamage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel wiill flicker. Additional Accessories- Shown Below

Find Similar Products by Category

Vendors Other Products

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Write your own product review

Click the button below to add the 4233 Differential Probe 1:10/100, 100 MHz, 700V to your wish list.