4234 Differential Probe 1:100/1000 , 100 MHz, 1400V

4234 Differential Probe 1:100/1000 , 100 MHz, 1400V

$675.00
Quantity

Product Description





Differential Probe for Power Management- Model 4234

The 4234 meets EN61010 Category III Requirements. With wide choice of
attenuation ratio, the 4234 is capable of making full range (from millivolts to ±1400V)
measurements of floating signals in power electronic circuits.

Features

-Bandwidth up to 100 MHz
-Up to +/-1400V(DC+Peak AC) Differential and Common Mode
-Safety Certified Applications
-Switching Power Supply Design
-Motor Drive Design
-Electronic Ballast Design
-CRT Display Design

Included

-Black Storage Box
-Red & Black Sprung Hooks
-Calibration Certificate
-4ea AA Batteries
-9 VDC Adapter

Product image

 

Optional 4200 Series Accessories

 

Included with Probe
blackbox.jpg
Black Storage
Box
&
9VDC Adapter
 
 
 
 
 
 
 
 
 

 

Model 4234 Specifications

Bandwidth DC-100MHz (-3dB)
Attenuation 1:100/1000
Rise Time 3.5 ns
Accuracy +/- 2%
Input Impedance 4 M Ohm //7pF each side to ground
Input Voltage
-Catagory
-Differential Range
-Common Mode Range
-Absolute Max. Voltage(Differential Or Common Mode)

 CAT III
140 Vrms and +/-140V(DC +Peak AC) @ 1/100
1000Vrms and +/-1400V(DC + Peak AC @1/1000
1000Vrms and +/-1400V(DC + Peak AC)@1/100 & 1/1000
1000Vrms and +/-1400V(DC +Peak AC)@1/100 & 1/1000
Output Voltage
-Swing
-Offset (typical)
-Noise(typical)
-Source Impedance (typical)
 
+/-7V (into 50kohm load)
<+5mV
0.9m Vrms
50 Ohm( for using 1 Mohm input system oscilloscope)
CMMR (typical) -80dB @650Hz, -50dB @ 1 MHz
 Ambient Operating temperature -10 to 40 degree centigrade
 Ambient Storage Temperature -30 to 70 degree centigrade
Ambient Operating Humidity Up to 85% RH
Ambient Storage Humidity Up to 85% RH
Length of Input Leads 12"
Length of BNC Cable 37"
Power Requirements* Standard 4 x AA cells or 9VDC Adapter (Both Included)
Options-Power Leads
Weight 0.9 lb
Dimensions (LxWxH) 8" x 3 1/4" x 1 1/2"

    Voltage limit is the lesser of the DC+Peak AC and RMS values 1000Vrms and + 1400V(DC + Peak AC) @1/100 & 1/1000
* a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe could be damaged or can¡¦t be operated properly.
b. polarity is "+" inside and "¡V" outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will flicker. Additional Accessories - Shown Below