Loading... Please wait...

4241 Differential Probe 1:100/1000

4241 Differential Probe 1:100/1000

$979.00
Quantity

Product Description





Differential Probe for High Voltage Power Measurement- Model 4241

The 4241 meets IEC61010-031 Category I Requirements and is ideally suited for measuring high-speed voltage surge in power electronics circuits.

Features
-Safety Certified-Over range Indicator
-Up to +/-7000 V(DC +Peak AC) Differential
-Bandwidth up to 70 MHz

Applications
-High Voltage Floating Measurements
-Voltage Surge Measurement
-Power Electronics System Design
-Electronic Ballast Design


Included
-Red & Black Sprung Hooks
-Calibration Certificate
-4ea AA Batteries
-9 VDC Adapter

Product image

 

Optional 4200 Series Accessories

Included with Probe
blackbox.jpg
Black Storage
Box
&
9VDC Adapter
 
 
 
 
 
 
 
 
 

 

Model 4241 Specifications

Bandwidth DC to 70MHz (-3dB)
Attenuation 1:100/1000
Input Impedance 10 M OHm/10pF each side to ground
Accuracy +/- 2%
Rise Time <5ns
Input Voltage
-Category

CAT I
-Differential Input Voltage 700Vrms and +/-700V (DC+Peak AC ) @ 1/100
5000Vrms and +/- 7000V (DC +Peak AC) @ 1/1000
-Common Mode Voltage 2500Vrms and+/-7000V (DC+ Peak AC) @ 1/100 & 1/1000
 -Absolute Max . Input 2500Vrms and +/-7000V (DC+ Peak AC) @ 1/100 & 1/1000 in Commom Mode
5000Vrms and +/-7000V (DC +Peak AC) @ 1/100 & 1/1000 in Differential Mode
Output Voltage

-Swing
-Offset (typical)
-Noise (typical)
-Source Impedance (typical)


+ 7V (into 50kohm load)
<+5mV
0.9m Vrms
50 Ohm (for using 1 Mohm input system oscilloscope)
CMRR (typical) -80dB @ 50Hz, -60dB @ 20kHZ
Ambient Operating temperature -10 to 40 degree centigrade
Ambient Storage temperature -30 to 70 degree centigrade
Ambient Operating humidity   Up to 85% RH
Ambient Storage humidity   Up to 85% RH
Power Requirements* Standard- 4 x AA cells or 9VDC adapter (Both Included)
Options- Power Leads
Length of Input Leads 23"
Length of BNC Cables 36"
Weight 0.9 lb
Dimensions (LxWxH) 8" x 3 1/4" x 1 1/2

 * a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe could be damaged or can¡¦t be operated properly.
b. polarity is "+" inside and "¡V" outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will flicker. Additional Accessories- Shown Below

Find Similar Products by Category

Vendors Other Products

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!