Product Description
Differential Probe for Power Measurement- Model 4231 (Discontinued -Suggested replacement Model PT-8002)
The 4231 is designed to safely analyze floating signals. The built in amplifier scales
and converts the high voltage differential input to a low, voltage single-ended BNC output,
compatible with any oscilloscope. The inputs are useful in measurements of power semiconductor circuits,
robotic drives, NC machines and the latest switching circuits.
Applications Features Price Includes |
Included with Probe
|
||
Black Storage Box
& 9VDC Adapter Included with Probe
|
__________________________________________________________________________________________________________________________________________
Click here for Optional 4200 Series Accessories
Model 4231 Specifications |
|
Bandwidth | DC to 25 MHz (-3dB) |
Attenuation Ratio | 1:20/200 |
Accuracy | +/- 2% |
Rise Time | 14ns |
Input Impedance | 4 Mohm//5.5pF each side to ground |
Input Voltage)** |
Cat III 140 Vrms and +/- 140V(DC + Peak AC) @ 1/20 1000 Vrms and +/-1400V(DC + Peak AC)@ 1/200 1000 Vrms and +/-1400V(DC + Peak AC) @ 1/20 & 1/200 1000 Vrms and +/-1400V(DC + Peak AC) @ 1/20 & 1/200 CAT III at 1/20 & 1/200 |
Output Voltage -Swing -Offset (typical) -Noise (typical) -Source Impedance (typical) |
|
CMMR (typical) | -80dB @ 50 Hz, -60dB @ 20kHz |
Ambient Operating Temperature | -10 to 40 degrees centigrade |
Ambient Storage Temperature | -30 to 70 degrees centigrade |
Ambient Operating Humidity | Up to 85% RH |
Ambient Storage Humidity | Up to 85% RH |
Power Requirements* | - Standard-4 x AA Cells , 9VDC/40mA Mains Adapter (Both Included) -Options-USB Power cord Power leads |
Length of BNC Cable | 37" |
Length of Input Leads | 17" |
Dimensions | 7 1/4" x 2 3/4" x 1" |
Weight | .583 lb |
Plugs 4mm Banana plugs | - Use with accessories below |
* a. The supplied voltage must be less than 12V and greater than 4.4V, or the probe could be damaged or will not operate properly.
b. polarity is "+" inside and "V" outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will flicker.
** (Input Voltage)The differential and common mode voltage range is the operating voltage range and the absolute voltage range is the safety voltage range.