Product Description
Differential Probe for Power Management- Model 4232 (Discontinued -Suggested replacement Model PT-8001)
The 4232 is designed to safely analyze floating signals. The built in amplifier scales and converts the high voltage differential
input to a low, voltage single-ended BNC output, compatible with any oscilloscope. The inputs are useful in
measurements of power semiconductor circuits, robotic drives, NC machines and the latest switching circuits.
Applications Features Cost Included |
|
Included with Probe
Black Storage
Case & 9VDC Adapter |
Optional 4200 Series Accessories
Model 4232 Specifications
Bandwidth | DC to 25 MHz (-3dB) |
Attenuation Ratio | 1:10/100 |
Accuracy | +/- 2% |
Rise Time | 14ns |
Input Impedance | 4 Mohm//5.5pF each side to ground |
Input Voltage** -Category -Differential Range -Common Mode Range -Absolute Max. Voltage(Differential or Common Mode) |
Cat III 70 Vrms and +/- 70V(DC + Peak AC)@ 1/10 700 Vrms and +/-700V(DC + Peak AC @ 1/100 700 Vrms and +/-700V(DC + Peak AC)@ 1/10 & 1/100 1000 Vrms and +/-1400V(DC + Peak AC@ 1/10 & 1/100 |
Output Voltage -Swing -Offset (typical) -Noise (typical) -Source Impedance (typical) |
+/- 7V( into 50 kohm load) <+/-5mV 0.7mVrms 50 ohm (for using 1 Mohm input system oscilloscope) |
CMMR (typical) | -80dB @ 50 Hz, -60dB @ 20kHz |
Ambient Operating Temperature | -10 to 40 degrees centigrade |
Ambient Storage Temperature | -30 to 70 degrees centigrade |
Ambient Operating Humidity | Up to 85% RH |
Ambient Storage Humidity | Up to 85% RH |
Power Requirements* | -Standard- 4 x AA Cells, 9VDC/40mA Mains Adapter (Both Included) -Options- USB Power cord Power leads |
Length of BNC Cable | 37" |
Length of Input Leads | 17" |
Dimension | 7 1/4" x 2 3/4" x 1" |
Weight | .583 lb |
Plugs 4mm Banana plugs | - Use with accessories below |
* a. The supplied voltage must be less than 12V and greater than 4.4V, or the probe could be damaged or will not operate properly.
b. polarity is "+" inside and "V" outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will flicker.
** (Input Voltage)The differential and common mode voltage range is the operating voltage range and the absolute voltage range is the safety voltage range.