Product Description
Differential Probe For Power Measurement- Model 4235 (Discontinued -Suggested replacement Model N1008A)
The 4235 meets EN61010 Category III requirements and is capable of making measurements of floating signals in power electronic circuits with +1% accuracy.
Features
-High Accuracy +1%
-Best CMRR in Power Measurement Probes -Smallest Size -Safety Certified Applications -Precise Power Semiconductor Device Measurement
-Switching Power Supply Design -Precise Measurement of Power Converter -Precise Measurement of Motor Drive Included -Black Storage Box
-Red & Black Sprung Hooks -Calibration Certificate -9 VDC Adapter |
Included with Probe
Black Storage Case
& 9VDC Adapter |
Optional 4200 Series Accessories
Model 4235 Specifications
Bandwidth | DC to 50 MHz(-3dB) |
Attenuation Ratio | 1/10 |
Accuracy | +/-1% |
Rise Time | <7ns |
Input Impedance | 1.6 Mohm/7pF each side to ground |
Input Voltage * -Category -Differential Input Voltage -Common Mode Voltage -Absolute Max. Voltage (Each side to ground) |
CAT l +/-70V(DC + Peak AC) 600Vrms and +/-700V (DC+Peak AC) 600Vrms and +/-700V (DC+Peak AC) |
Output Voltage -Swing (into 50 kOhm load) -Offset (typical) -Noise (typical) -Source Impedance (typical) |
+/-7V <+/-2mV 0.7mVrms 50 Ohm (for using 1Mohm input system oscilloscope) |
CMRR (typical) | -90dB @ 60 Hz, -60dB @ 1 Mhz |
Ambient Operating Temperature | -10 to 40 degree centigrade |
Ambient Storage Temperature | -30 to 70 degree centigrade |
Ambient Operating Humidity | Up to 85% RH |
Ambient Storage Humidity | Up to 85% RH |
Length of BNC Cable | 49" |
Length of Input Leads | 20" |
Power Requirement Options** | Included 9VDC adapter, (Optional- Power leads or Removable battery pack uses 4ea. AA cells) |
Weight Dimensions | (LxWxH) 0.4 lb4 1/2" x 1" x 1/2" |
*Voltage limit is the lesser of the DC+Peak AC and RMS values.
** a. The supplied voltage must be less than 16V and greater than 3.3V, or the probe could be damaged or will not operate properly.
b. For wrong polarity of power sources, a built-in circuit will protect the probe and no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will dim and then distinguish
** a. The supplied voltage must be less than 16V and greater than 3.3V, or the probe could be damaged or will not operate properly.
b. For wrong polarity of power sources, a built-in circuit will protect the probe and no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will dim and then distinguish