Product Description
Differential Probe for High Voltage Power Measurement - Model 4241A (Discontinued- Suggested replacement PT-8020)
The 4241A meets IEC61010-031 Category I Requirements and is ideally suited for measuring
high-speed voltage surge in power electronics circuits.
high-speed voltage surge in power electronics circuits.
Features
-Up to + 7000V(DC +Peak AC) Differential
-Bandwidth up to 70MHZ -Safety Certified -Over range Indicator Applications
-High Voltage Floating Measurement
-Voltage Surge Measurement -Power Electronics System Design -Electronic Ballast Design Included
-High Voltage Sprung Hooks Red & Black (7000V CAT I , 2A)
-Calibration Certificate -4ea AA Batteries -9 VDC Adapter -Black storage case |
Included with Probe
Black Storage
Box & 9VDC Adapter |
Model 4241A Specifications |
|
Bandwidth | DC to 70MHz (-3dB) |
Attenuation | 1:100/1000 |
Accuracy | + 2% |
Input Impedance | 50 M OHm/10pF each side to ground |
Input Voltage -Category |
CAT I |
-Differential Range* | 500Vrms and +700V (DC+Peak AC) @ 1/100 5000Vrms and +7000V (DC+Peak AC) @1/1000 |
-Common Mode Range* | 5000Vrms and+7000V (DC+Peak AC) @ 1/100 & 1/1000 |
-Absolute Max. Voltage* (Differential or Common Mode) |
5000Vrms and+7000V (DC+Peak AC) @ 1/100 & 1/1000 |
Output Voltage -Swing (into 50kohm load) -Offset (typical) -Noise (typical) -Source Impedance (typical) |
+ 7V <+5mV 0.9m Vrms 50 Ohm ( for using 1Mohm input system oscilloscope) |
CMRR (typical) | -80dB @ 50Hz, -60dB @ 20Hz |
Ambient Operating Temperature | -10 to 40 degree centigrade |
Ambient Storage Temperature | -30 to 70 degree centigrade |
Ambient Operating Humidity | Up to 85% RH |
Ambient Storage Humidity | Up to 85% RH |
Power Requirements** | Standard 4 x AA cells or 9VDC adapter (Both Included) Options Power Leads |
Length of BNC Cable | 26" |
Length of Input Leads | 23" |
Weight | 0.9 lb |
Dimensions | (LxWxH) 8" x 3 1/4" x 1 1/2" |
*Voltage limit is the lesser of the DC+Peak AC and RMS values.
**a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe could be damaged
or will not operate properly.
b. polarity is "+" inside and "¡V" outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will flicker.
**a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe could be damaged
or will not operate properly.
b. polarity is "+" inside and "¡V" outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will flicker.
d. The adjustment screw on the front panel of the unit is the output offset adjustment. The output offset adjustment is to adjust
the output voltage to zero before measuring.